- Y2 Series Medium size Three phase Induction Motors
- * Frame sizes: 355-560 * Rated output: 185-1600kW * Insulation class: F * Degree of protection: IP54 * Enclosure: IC411 * Rotor: Squirrel cage * Voltage: 6Kv, 10Kv * Mounting: Horizontal
- YE3 Series IE3 Super high Efficiency Three phase induction motors
- * Frame sizes: 63 to 355
* Rated output: 0.12 to 400kW
* Voltage: 380V
* Frequency: 50Hz or 60Hz
* Number of poles: 2, 4, 6, 8,10
* Efficiency levels: IE3
* Duty Cycle: S1
* Enclosure: IC411 - TEFC
* Insulation class: F
* Degree of protection: IP56 / IP65
- Z4 Series DC Motors
- * Frame sizes: 100-450 * Rated output: 1.5-600kW * Insulation class: F * Voltage:160V / 440V * Duty cycle: S1 * Excitation mode: Separate excitation * Rotation speed: 3000,1500,1000,750,600,500,400,300,200r/min
- YC Series Capacitor Start & Run Induction Motors
- * Frame sizes: 71 to 132 * Rated output: 0.12 to 3.7kW * Voltage: 220V,110V/220V, 110V, 240V * Frequency: 50Hz or 60Hz * Duty cycle: S1 * Insulation class: B / F * Number of poles: 2,4,6
- YVF2 Series Frequency Variable Speed Regulation Motors
- * Frame sizes: 80 to 355
* Rated output: 0.18 to 375kW
* Insulation class: F
* Voltage: 380V
* Efficiency levels: IE1
* Frequency range for 2P:
(3) 5-100Hz (frame size 80-250)
(3) 5-70Hz (frame size 280)
(3) 5-60Hz (frame size 315-355)
* Frequency range for 4, 6, 8, 10P: (3) 5-100Hz- NEP Series Premium Efficient NEMA motor
- * Frame:140T ~ 440T * Rated Power:1HP ~ 250 HP * Poles:2, 4, 6 * AC Voltage:230/460V,575V * Frequency:50/60 Hz * Insulation Class:F * Protection Grade:IP55 * Efficiency:Premium Efficient
- YKK Series High Voltage Three Phase Induction Motors
- * Frame sizes: 355-1000 * Rated output: 185-8000kW * Insulation class: F * Degree of protection: IP54 /IP55 * Enclosure: IC611 * Mounting: Horizontal * Rotor: Squirrel cage * Bearing: Rolling bearing or sleeve bearing * Voltage: 6kV, 10kV * Efficiency: IE1 & IE2 & IE3
- YLVF Series low-voltage high-power inverter three-phase asynchronous motor
- * Frame sizes: 400 to 450 * Rated output: 185 to 800kW * Insulation class: F * Voltage: 380V * Frequency range for 2P: (3) 5-60Hz (frame size 400-450) * Frequency range for 4, 6, 8, 10P: (3) 5-100Hz
Top articles
Latest articles
- National May Day Labor Medal
- Chinese New Year
- Top 100 Comprehensive Manufacturing Enterprises of Private Enterprises in Anhui Province in 2023
- IE4 efficiency Explosion-proof motor has successfully passed the national supervision and random inspection
- Welcome new people to join Wannan Motor
- Wannan Motor successfully participated in EASA Fair
- IE5 efficiency Flameproof Motor
- The first successful of the cast aluminum technical transformation project
- New Office Building
- "Anhui Province 2022 Private Enterprise Manufacturing Comprehensive Top 100 enterprises"
Your browsing history
Why use high voltage motors?
Most of hybrid vehicles such as Toyota Prius use high voltagemotors which reach voltages beyond 500 V.Such high voltages are dangerous and require assembly frommany hundreds of batteries.In one place I`ve read that powerelectric motor draws is related to volts times amps.I whish to know why because I thought magnetic field strengthwhich is created around wire depends on current but not onvoltage.Electric motor mostly works on magnetic field strength.